1.
Rev. colomb. biotecnol ; 17(1): 79-90, ene.-jun. 2015. ilus, tab
Article in Spanish | LILACS | ID: lil-751192

ABSTRACT

El ritmo de vida actual, tanto sociocultural como tecnológico, ha desembocado en un aumento de enfermedades y padecimientos que afectan las capacidades físico-motrices de los individuos. Esto ha originado el desarrollo de prototipos para auxiliar al paciente a recuperar la movilidad y la fortaleza de las extremidades superiores afectadas. El presente trabajo aborda el diseño de una estructura mecánica de un exoesqueleto con 4 grados de libertad para miembro superior. La cual tiene como principales atributos la capacidad de ajustarse a la antropometría del paciente mexicano (longitud del brazo, extensión del antebrazo, condiciones geométricas de la espalda y altura del paciente). Se aplicó el método BLITZ QFD para obtener el diseño conceptual óptimo y establecer adecuadamente las condiciones de carga de servicio. Por lo que, se definieron 5 casos de estudio cuasi-estáticos e implantaron condiciones para rehabilitación de los pacientes. Asimismo, mediante el Método de Elemento Finito (MEF) se analizaron los esfuerzos y deformaciones a los que la estructura está sometida durante la aplicación de los agentes externos de servicio. Los resultados presentados en éste trabajo exhiben una nueva propuesta para la rehabilitación de pacientes con problemas de movilidad en miembro superior. Donde el equipo propuesto permite la rehabilitación del miembro superior apoyado en 4 grados de libertad (tres grados de libertad en el hombro y uno en el codo), el cual es adecuado para realizar terapias activas y pasivas. Asimismo, es un dispositivo que está al alcance de un mayor porcentaje de la población por su bajo costo y fácil desarrollo en la fabricación.


The pace of modern life, both socio-cultural and technologically, has led to an increase of diseases and conditions that affect the physical-motor capabilities of persons. This increase has originated the development of prototypes to help patients to regain mobility and strength of the affected upper limb. This work, deals with the mechanical structure design of an exoskeleton with 4 degrees freedom for upper limb. Which has the capacity to adjust to the Mexican patient anthropometry (arm length, forearm extension, geometry conditions of the back and the patient's height) BLITZ QFD method was applied to establish the conceptual design and loading service conditions on the structure. So, 5 quasi-static cases of study were defined and conditions for patient rehabilitation were subjected. Also by applying the finite element method the structure was analyzed due to service loading. The results presented in this work, show a new method for patient rehabilitation with mobility deficiencies in the upper limb. The proposed new design allows the rehabilitation of the upper limb under 4 degrees of freedom (tree degrees of freedom at shoulder and one at the elbow), which is perfect to perform active and passive therapy. Additionally, it is an equipment of low cost, which can be affordable to almost all the country population.

2.
Rev. colomb. biotecnol ; 15(1): 28-41, ene.-jun. 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-696142

ABSTRACT

El desgaste de los insertos de Polietileno de Ultra-Alto Peso Molecular (UHMWPE pos sus siglas en inglés) continúa afectando la longevidad de las prótesis totales de rodilla (PTR) junto con el aflojamiento aséptico, y ambos constituyen las dos principales causas de falla de las prótesis. Considerando esto, es necesario encontrar soluciones adecuadas para evitar el desgaste excesivo y hasta la ruptura de los insertos de polietileno. En este trabajo se realizó el estudio mediante simulación numérica de una PTR Scorpio II® Stryker®, la cual se retiró por desgaste del inserto de UHMWPE en el Hospital 1° de Octubre del ISSSTE en México. Se utilizaron las hipótesis de Bartel et al. (1995) y Chillag et al. (1991) para la validación del método numérico utilizado, las cuales establecen que el desgaste del polietileno puede reducirse utilizando insertos tibiales de mayor espesor, lo cual disminuye las presiones de contacto. Los análisis se realizaron mediante MEF variando el espesor del inserto de 6, 8, 10, 12 y 14 mm, suponiendo cargas axiales de tipo cuasi-estático en la articulación a cero grados de flexión, para 1.33 veces el peso de un individuo de 75 kg (736 N) empleando el ciclo normalizado de marcha. Los resultados obtenidos muestran similitud con los reportados por Bei et al. (2004) y Deen et al. (2006). Después de validar el método, se desarrolló el modelo de MEF de la PTR y se determinaron las curvas de esfuerzo y de áreas de contacto del inserto de UHMWPE, con lo que se obtuvo información importante para modificar el diseño y obtener una prótesis de geometría conforme en los planos coronal y sagital del inserto femoral y el inserto de polietileno, de acuerdo con el fenotipo mexicano.


Wear of UHMWPE inserts continues affecting the longevity of total knee replacements (TKR) together with septic loosening, and both constitute two main causes of prosthesis failure. It is necessary to find appropriate solutions to avoid excessive wear and failure of polyethylene inserts. In this work a study was carried out by means of numeric simulation of a Scorpio II® Stryker® TKR, which was retired due to wear of UHMWPE in the Hospital 1° de Octubre of ISSSTE in Mexico city. Hypotheses of Bartel et al. (1995) and Chillag et al. (1991) were used, which settle down that wear of polyethylene can decrease using thicker tibial inserts, which can be reduced contact pressures. Analyses of this work was carried out by means of FEM varying insert thickness of 6, 8, 10, 12 and 14 mm, considered quasi-static axial loads actuating on the articulation with zero degrees of flexion and loads equivalent to 1.33 times of bodyweight of a subject of 75 kg (736 N) was considered. Normalized gait cycle was employed and results obtained are similar to those reported by Bei et al. (2004) and Deen et al. (2006). After validating the method, a model of study case of TKR in FEM was developed and the curves of stress and contact areas of UHMWPE were determined, with which important information was obtained to modify the design, as well as to obtain a prosthesis of optimal conformity in both coronal and sagital planes of the femoral and UHMWPE inserts, in agreement with characteristics of the Mexican phenotype.


Subject(s)
Humans , Knee , Numerical Analysis, Computer-Assisted , Prostheses and Implants , Polyethylene , Pressure
3.
Rev. colomb. biotecnol ; 12(2): 41-54, dic. 2010. ilus
Article in Spanish | LILACS | ID: lil-590773

ABSTRACT

En México, la mortalidad debido a enfermedades bronco-respiratorias se ubica en el sexto lugar según datos estadísticos dados por el Instituto Nacional de Enfermedades Respiratorias (INER). Esto genera la necesidad de incrementar la eficiencia en la aplicación de los tratamientos usados para este tipo de patología. Algunos de los métodos utilizados con mayor frecuencia para el tratamiento de estas dolencias hacen uso de micro dispositivos, también conocidos como válvulas endobronquiales. Este es un sistema alternativo que evita cirugías invasivas y logra prolongar e incrementar la calidad de vida de los pacientes. En este trabajo se presenta el análisis del desempeño de la válvula IBV®. Para el desarrollo del estudio numérico se determinaron las dimensiones y propiedades mecánicas del modelo a partir de catálogos del fabricante. Se desarrolló un modelo para el cual se consideraron las propiedades del Nitinol® y Silastic®. Asimismo, se propusieron dos condiciones de operación para la válvula, una anclada en el bronquio y la otra en la condición en la que se encuentra plegada dentro del broncoscopio. Se utilizó el Método del elemento finito (MEF) para simular las condiciones de trabajo de la válvula. Los resultados encontrados muestran el funcionamiento estructural y el nivel de los esfuerzos generados en el implante durante el ciclo de respiración forzada del individuo. Además, se proporcionan las bases para generar un nuevo dispositivo que pueda emular el funcionamiento de este tipo de implantes y aumente la eficiencia del tratamiento de dicha patología.


In Mexico, the mortality rate due to bronchial respiratory sickness is placed in the sixth position, according to statistics from the National Institute of Breathing Sickness (INER), so it is convenient to increment the efficiency of treatments for those pathologies. The intrabronchial valve is a recommended alternative method; being it main objective to avoid invasive surgery and increase the time and quality of patient´s life. Within this work a biomechanical analysis of an IBV® valve is carried out. Regarding the numerical analysis, the dimensions and mechanical properties of the valve were proposed based on catalogues published by the manufacturer as more reliable information was not available in the open literature. As a result, a new model was developed in which both materials Nitinol® and Silastic® are considered as the main valve materials. The proposed working conditions assume that the valve is implanted in folded form at the bronchus and then anchored when it is unfolded. Finite Element Method (FEM) was used to simulate the proposed working conditions. Results obtained show the structural performance and the level of stress generated in the implant during the breathing cycle. In addition, it provides the knowledge to generate a new device that could emulate the performance of these implants and develop a more efficient treatment this disease.


Subject(s)
Lung Neoplasms/surgery , Lung Neoplasms/diagnosis , Lung Neoplasms/nursing , Lung Neoplasms/epidemiology , Lung Neoplasms/physiopathology , Lung Neoplasms/chemically induced , Lung Neoplasms/pathology , Lung Neoplasms/chemistry , Lung Neoplasms/drug therapy , Heart Valves/abnormalities , Heart Valves/physiology , Heart Valves/immunology , Heart Valves/pathology , Heart Valves/chemistry
4.
Rev. colomb. biotecnol ; 10(2): 14-22, dic. 2008. ilus, graf
Article in Spanish | LILACS | ID: lil-505449

ABSTRACT

La espectroscopia mediante celda fotoacústica diferencial (CFD) tiene la capacidad de medir in situ el desarrollo de diversos procesos dinámicos, entre otros la difusión de agua a través de una membrana. Mediante esta técnicase realizó el estudio de permeación de agua en huesos de rata Wistar sanos y descalcificados. Los huesos descalcificados fueron tratados mediante estimulación electromagnética a fin de evaluar la actividad celular en el hueso y, en su caso, detener la descalcificación del mismo. En este trabajo fue posible determinar la viabilidad de la CFD para la evaluación de densidad ósea indirectamente, siendo posible efectuar la evaluación in situ de permeación de agua, así como la cantidad de agua retenida en la estructura ósea al finalizar las pruebas en CFD.


Subject(s)
Electromagnetic Phenomena , Bone and Bones/radiation effects , Osteoporosis
SELECTION OF CITATIONS
SEARCH DETAIL